Search icon

Delta Fabrication, LLC

Company Details

Name: Delta Fabrication, LLC
Jurisdiction: MISSISSIPPI
Business Type: Limited Liability Company
Status: Good Standing
Effective Date: 17 Jan 2008 (17 years ago)
Business ID: 925571
ZIP code: 38701
County: Washington
State of Incorporation: MISSISSIPPI
Principal Office Address: 1091-B LITTLE THEATER ROADGREENVILLE, MS 38701

Agent

Name Role Address
Ernest W. Stewart Esq Agent 7716 Old Canton Road, Suite B, Madison, MS 39110

Manager

Name Role Address
Bobby Brown Manager 1421 Lakehall Road, Lake Village, AR 71653

Member

Name Role Address
Bobby Brown Member 1421 Lakehall Road, Lake Village, AR 71653

Filings

Type Status Filed Date Description
Annual Report LLC Filed 2024-10-03 Annual Report For Delta Fabrication, LLC
Notice to Dissolve/Revoke Filed 2024-09-01 Notice of Intent to Dissolve: AR: Delta Fabrication, LLC
Amendment Form Filed 2023-02-28 Amendment For Delta Fabrication, LLC
Reinstatement Filed 2023-01-03 Reinstatement For Delta Fabrication, LLC
Admin Dissolution Filed 2022-11-28 Action of Intent to Dissolve: AR: Delta Fabrication, LLC
Notice to Dissolve/Revoke Filed 2022-09-05 Notice of Intent to Dissolve: AR: Delta Fabrication, LLC
Annual Report LLC Filed 2021-11-16 Annual Report For Delta Fabrication, LLC
Notice to Dissolve/Revoke Filed 2021-09-07 Notice of Intent to Dissolve: AR: Delta Fabrication, LLC
Annual Report LLC Filed 2020-08-17 Annual Report For Delta Fabrication, LLC
Annual Report LLC Filed 2019-10-02 Annual Report For Delta Fabrication, LLC

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342859345 0419400 2017-12-21 1091 B LITTLE THEATER ROAD, GREENVILLE, MS, 38703
Inspection Type FollowUp
Scope Partial
Safety/Health Health
Close Conference 2017-12-21
Case Closed 2018-01-04

Related Activity

Type Inspection
Activity Nr 1220563
Health Yes
342205630 0419400 2017-03-28 1091 B LITTLE THEATER ROAD, GREENVILLE, MS, 38703
Inspection Type Planned
Scope Complete
Safety/Health Health
Close Conference 2017-03-28
Emphasis N: SILICA, P: SILICA
Case Closed 2018-01-18

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100141 D02 II
Issuance Date 2017-04-13
Current Penalty 1939.2
Initial Penalty 3232.0
Final Order 2017-04-25
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.141(d)(2)(ii): Lavatories were not provided with hot and cold, or tepid running water: (a) Bathrooms - On or about March 28, 2017 there was no hot water in the bathrooms.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100141 D02 III
Issuance Date 2017-04-13
Abatement Due Date 2017-04-25
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-04-25
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.141(d)(2)(iii): Lavatories were not provided with hand soap or similar cleansing agent: (a) Men Bathroom - On or about March 28, 2017 there was not hand soap in the men bathroom.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19100141 D02 IV
Issuance Date 2017-04-13
Abatement Due Date 2017-04-25
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-04-25
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.141(d)(2)(iv): Lavatories were not provided with individual hand towels or sections thereof, of cloth or paper, warm air blowers or clean individual sections of continuous cloth toweling: (a) Men Bathroom - On or about March 28, 2017 no hand towels or warm air blower was provided in the men bathroom.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100212 A03 II
Issuance Date 2017-04-13
Current Penalty 2586.0
Initial Penalty 4310.0
Final Order 2017-04-25
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) North Shop - On or about March 28, 2017 the back side of the band saw was not guarded.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100303 F01
Issuance Date 2017-04-13
Current Penalty 1939.2
Initial Penalty 3232.0
Final Order 2017-04-25
Nr Instances 2
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(f)(1): Each disconnecting means required by Subpart S of Part 1910 for motors and appliances was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: (a) Break Room - On or about March 28, 2017 the switches in the electrical box was not marked to indicate its purpose. (b) North Shop East Wall - On or about March 28, 2017 the switches in the electrical box was not marked to indicate its purpose. (c) Plasma Bay - On or about March 28, 2107 the switches in the electrical box was not marked to indicate its purpose.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100303 G02 I
Issuance Date 2017-04-13
Current Penalty 3232.2
Initial Penalty 5387.0
Final Order 2017-04-25
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): (a) Break Room - On or about March 28, 2017 live wires at the breaker box was not guarded from accidental contact. (b) Break Room - On or about March 28, 2017 lives wires were protruding out of wall receptacle under the grey electrical breaker box.
Citation ID 01005
Citaton Type Serious
Standard Cited 19100305 B01 II
Issuance Date 2017-04-13
Current Penalty 2586.0
Initial Penalty 4310.0
Final Order 2017-04-25
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed. (a) North Shop - On or about March 28, 2017, electrical breaker box located on the east wall had unused openings that were not covered.
Citation ID 02001
Citaton Type Other
Standard Cited 19100178 L01 I
Issuance Date 2017-04-13
Abatement Due Date 2017-04-25
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-04-25
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): (a) North Shop - On or about March 28,2017 the employer has not ensured that the forklift operators are competent to operate a forklift.
Citation ID 02002
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2017-04-13
Abatement Due Date 2017-04-25
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-04-25
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) Shop - On or about March 28, 2017 the employer had not developed or implemented a written Hazard Communication Program.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
4829297000 2020-04-04 0470 PPP 1091 LITTLE THEATER RD #B, GREENVILLE, MS, 38703-8242
Loan Status Date 2021-09-29
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 422900
Loan Approval Amount (current) 422900
Undisbursed Amount 0
Franchise Name -
Lender Location ID 4089
Servicing Lender Name Southern Bancorp Bank
Servicing Lender Address 601 Main St, Arkadelphia, AR, 71923
Rural or Urban Indicator U
Hubzone Y
LMI Y
Business Age Description Existing or more than 2 years old
Project Address GREENVILLE, WASHINGTON, MS, 38703-8242
Project Congressional District MS-02
Number of Employees 33
NAICS code 332312
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Limited Liability Company(LLC)
Originating Lender ID 4089
Originating Lender Name Southern Bancorp Bank
Originating Lender Address Arkadelphia, AR
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 428565.7
Forgiveness Paid Date 2021-08-10

Motor Carrier Census

USDOT Number Carrier Operation MCS-150 Form Date MCS-150 Mileage MCS-150 Year Power Units Drivers Operation Classification
2368297 Interstate 2023-09-07 2567 2022 2 2 Private(Property)
Legal Name DELTA FABRICATION LLC
DBA Name -
Physical Address 1091B LITTLE THEATER ROAD, GREENVILLE, MS, 38701, US
Mailing Address P O BOX 4475, GREENVILLE, MS, 38704, US
Phone (662) 335-2500
Fax (662) 335-2250
E-mail DELTAFABRICATION@ATT.NET

Safety Measurement System - All Transportation

Total Number of Inspections for the measurement period (24 months) 0
Driver Fitness BASIC Serious Violation Indicator No
Vehicle Maintenance BASIC Acute/Critical Indicator No
Unsafe Driving BASIC Acute/Critical Indicator No
Driver Fitness BASIC Roadside Performance measure value 0
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value 0
Total Number of Driver Inspections for the measurment period 0
Vehicle Maintenance BASIC Roadside Performance measure value 0
Total Number of Vehicle Inspections for the measurement period 0
Controlled Substances and Alcohol BASIC Roadside Performance measure value 0
Unsafe Driving BASIC Roadside Performance Measure Value 0
Number of inspections with at least one Driver Fitness BASIC violation 0
Number of inspections with at least one Hours-of-Service BASIC violation 0
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation 0
Number of inspections with at least one Vehicle Maintenance BASIC violation 0
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation 0
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation 0
Number of inspections with at least one Unsafe Driving BASIC violation 0

Date of last update: 13 Feb 2025

Sources: Mississippi Secretary of State