346798044
|
0419400
|
2023-06-27
|
2300 MUNSFORD DRIVE, NEW ALBANY, MS, 38652
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-06-27
|
Emphasis |
L: FORKLIFT
|
Case Closed |
2023-07-12
|
Related Activity
Type |
Complaint |
Activity Nr |
2044658 |
Safety |
Yes |
|
|
343690525
|
0419400
|
2019-01-03
|
2300 MUNSFORD DRIVE, NEW ALBANY, MS, 38652
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2019-01-03
|
Case Closed |
2019-02-04
|
Related Activity
Type |
Inspection |
Activity Nr |
1357629 |
Safety |
Yes |
|
|
343576294
|
0419400
|
2018-11-01
|
2300 MUNSFORD DRIVE, NEW ALBANY, MS, 38652
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-11-01
|
Emphasis |
L: AUTOSUP
|
Case Closed |
2019-01-03
|
Related Activity
Type |
Complaint |
Activity Nr |
1396559 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100303 B02 |
Issuance Date |
2018-12-12 |
Abatement Due Date |
2018-12-28 |
Current Penalty |
4711.8 |
Initial Penalty |
7853.0 |
Final Order |
2018-12-20 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling. (a) Injection Molder 2200 - On or about November 01, 2018 an electrical outlet box designed to be mounted at a fixed location was being used as an extension cord. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100305 B01 II |
Issuance Date |
2018-12-12 |
Abatement Due Date |
2018-12-28 |
Current Penalty |
4711.8 |
Initial Penalty |
7853.0 |
Final Order |
2018-12-20 |
Nr Instances |
3 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed. (a) Injection Molding - On or about November 01, 2018 unused openings on 480 volt 3 phase electrical outlet boxes were not closed. - Injection Molder 390 - Injection Molder 950-1 - Injection Molder 2200 |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100305 B02 I |
Issuance Date |
2018-12-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-12-20 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose. (a) Injection mold 950-2 - On or about November 01, 2018 480 volt 3 phase outlet box was missing the cover plate. - Injection Molder 950-2 - Injection Molder110 |
|
Citation ID |
02001A |
Citaton Type |
Other |
Standard Cited |
19100303 B07 |
Issuance Date |
2018-12-12 |
Abatement Due Date |
2018-12-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-12-20 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(b)(7): 29 CFR 1910.303(b)(7): Electrical equipment was not installed in a neat and workmanlike manner. (a) Hazmat Area - On or about November 01, 2018 energized 208 volt single phase temporary flexible conductor was not installed in a neat and workmanlike manner. |
|
Citation ID |
02001B |
Citaton Type |
Other |
Standard Cited |
19100305 B01 I |
Issuance Date |
2018-12-12 |
Abatement Due Date |
2018-12-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-12-20 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. (a) Hazmat Area - On or about November 01, 2018 energized 208 volt single phase temporary flexible conductor was not protected from abrasion. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100305 G02 III |
Issuance Date |
2018-12-12 |
Abatement Due Date |
2018-12-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-12-20 |
Nr Instances |
2 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to the joints or terminal screws: (a) Injection Molding - On or about November 01, 2018 the outer sheathing was not connected to the strain relief connector. - No. 67 Thermulator - Injection Molder 2800 |
|
|
342764925
|
0419400
|
2017-11-09
|
1200 MAGNOLIA WAY, BLUE SPRINGS, MS, 38828
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2017-11-29
|
Emphasis |
L: AUTOSUP
|
Case Closed |
2018-02-05
|
Related Activity
Type |
Referral |
Activity Nr |
1281906 |
Safety |
Yes |
|
|
341171247
|
0419400
|
2016-01-12
|
2300 MUNSFORD DRIVE, NEW ALBANY, MS, 38652
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2016-01-13
|
Emphasis |
L: AUTOSUP, P: AUTOSUP
|
Case Closed |
2016-04-15
|
Related Activity
Type |
Inspection |
Activity Nr |
1117836 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100022 A02 |
Issuance Date |
2016-04-05 |
Current Penalty |
2167.8 |
Initial Penalty |
3613.0 |
Final Order |
2016-04-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition: (a) Component Rack, Storage - On or about January 13, 2016 a puddle of oil was on the floor next to a component rack in the storage area. The oil leaked from a box. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100176 B |
Issuance Date |
2016-04-05 |
Current Penalty |
1300.8 |
Initial Penalty |
2168.0 |
Final Order |
2016-04-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.176(b): Storage was not secure. Storage of material shall not create a hazard. Bags, containers, bundles, etc., stored in tiers shall be stacked, blocked, interlocked and limited in height so that they are stable and secure against sliding or collapse. (a) Storage, Component Rack - On or about January 13, 2016 a small pallet stored on the second tier of a component rack next to storage rack section A-2635 was not stored securely. The pallet was leaning against an adjacent pallet. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100305 E01 |
Issuance Date |
2016-04-05 |
Abatement Due Date |
2016-04-07 |
Current Penalty |
2040.0 |
Initial Penalty |
3400.0 |
Final Order |
2016-04-14 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures were not weatherproof in wet locations: (a) Battery Charging Area - On or about January 13, 2016 an emergency shower/eyewash station was placed 16 inches from 480 volts/3 phase battery charging units. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100157 G01 |
Issuance Date |
2016-04-05 |
Abatement Due Date |
2016-04-07 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-04-14 |
Nr Instances |
1 |
Nr Exposed |
120 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting. (a) Plant - On or about January 13, 2016 employees who are expected to fight fires in the recipient stage had not received fire extinguisher training. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100184 E01 |
Issuance Date |
2016-04-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-04-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.184(e)(1): Alloy steel sling(s) did not have permanently affixed durable identification stating size, grade, rated capacity, and reach. (a) Injection, Crane No. 1 - On or about January 13, 2016 two double slings hooked to a 20 ton crane did not have an identification tags. |
|
|
337548416
|
0419400
|
2012-11-27
|
2300 MUNSFORD DRIVE, NEW ALBANY, MS, 38652
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2012-12-18
|
Case Closed |
2012-12-27
|
Related Activity
Type |
Referral |
Activity Nr |
660632 |
Health |
Yes |
|
|
337056386
|
0419400
|
2012-10-24
|
2300 MUNSFORD DRIVE, NEW ALBANY, MS, 38652
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-10-24
|
Emphasis |
L: FORKLIFT
|
Case Closed |
2012-11-29
|
Related Activity
Type |
Complaint |
Activity Nr |
625051 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 C01 |
Issuance Date |
2012-11-08 |
Abatement Due Date |
2012-11-19 |
Current Penalty |
2295.0 |
Initial Penalty |
3825.0 |
Final Order |
2012-12-04 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. Jobsite - On or about October 24, 2012 the facility does not have a written energy control program that has equipment listed, specific lock out procedures to deenergize the equipment, person/s responsible for conducting periodic inspections and certification of training of affected and authorized employees that is related to their specific machinery. 2200 Injection Molder and 2800 Injection Molder are some of the equipment at the jobsite. |
|
|
335379392
|
0419400
|
2012-07-12
|
1200 MAGNOLIA WAY, BLUE SPRINGS, MS, 38828
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2012-08-31
|
Case Closed |
2012-10-09
|
Related Activity
Type |
Complaint |
Activity Nr |
415051 |
Health |
Yes |
|
|
334515335
|
0419400
|
2012-05-18
|
1200 MAGNOLIA WAY, BLUE SPRINGS, MS, 38828
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2012-08-31
|
Case Closed |
2012-10-09
|
Related Activity
Type |
Complaint |
Activity Nr |
346298 |
Health |
Yes |
|
|