344789243
|
0419400
|
2020-06-11
|
976 HIGHWAY 45, BALDWYN, MS, 38824
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2020-06-30
|
Case Closed |
2023-03-29
|
Related Activity
Type |
Referral |
Activity Nr |
1602256 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 D02 |
Issuance Date |
2020-11-12 |
Abatement Due Date |
2020-12-07 |
Current Penalty |
4337.4 |
Initial Penalty |
7229.0 |
Final Order |
2020-12-09 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: (a) Work Area - On or about June 3, 2020 the employee cleaning the glue roller machine was exposed to an amputation hazard, in that the roller machine was not locked out. |
|
|
343168696
|
0419400
|
2018-05-18
|
134 LIPFORD DR., VERONA, MS, 38879
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-05-18
|
Case Closed |
2018-06-04
|
Related Activity
Type |
Complaint |
Activity Nr |
1337970 |
Safety |
Yes |
|
|
340912666
|
0419400
|
2015-09-04
|
154 LIPFORD RD, VERONA, MS, 38879
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2015-09-04
|
Case Closed |
2015-09-17
|
Related Activity
Type |
Inspection |
Activity Nr |
1059554 |
Safety |
Yes |
|
|
340595545
|
0419400
|
2015-04-28
|
154 LIPFORD RD, VERONA, MS, 38879
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-04-28
|
Case Closed |
2015-07-28
|
Related Activity
Type |
Complaint |
Activity Nr |
978619 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100023 C01 |
Issuance Date |
2015-06-30 |
Abatement Due Date |
2015-07-23 |
Current Penalty |
4200.0 |
Initial Penalty |
7000.0 |
Final Order |
2015-07-24 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.23(c)(1): Open-sided floor(s) or platform(s) 4 feet (1.22 m) or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides: (a) North Crane - On or about April 28, 2015 the crane catwalk was missing a guardrail. The catwalk was 19 feet above the ground. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100179 G02 I |
Issuance Date |
2015-06-30 |
Abatement Due Date |
2015-07-23 |
Current Penalty |
2040.0 |
Initial Penalty |
3400.0 |
Final Order |
2015-07-24 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.179(g)(2)(i): Electrical equipment was not so located or enclosed that live parts would not be exposed to accidental contact under normal operating conditions. (a) North Crane - On or about April 28, 2015 operator of the overhead cab operated crane was exposed to open electical live parts inside the cab and along the walkway to the cab. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100179 J01 II B |
Issuance Date |
2015-06-30 |
Abatement Due Date |
2015-07-23 |
Current Penalty |
2550.0 |
Initial Penalty |
4250.0 |
Final Order |
2015-07-24 |
Nr Instances |
3 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.179(j)(1)(ii)(b): 29 CFR 1910.179(j)(3): A complete periodic inspection of crane(s) had not been conducted in the past 12 months: (a) Facility - On or about April 22, 2015 overhead cranes have not been inspected in the last 12 months. - North Cab-Operated Crane - South Cab-Operated Crane - Auto Crane |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100023 E03 V B |
Issuance Date |
2015-06-30 |
Abatement Due Date |
2015-07-23 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-07-24 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.23(e)(3)(v)(b): Railing construction type, size and/or arrangement did not meet the minimum requirement of strength to withstand at least 200 pounds top rail pressure: (a) North Crane - On or about March 28, 2015 the top guardrail end was not attached to the upright guardrail post because of a broken weld. |
|
|
340124387
|
0419400
|
2014-12-08
|
154 LIPFORD RD, VERONA, MS, 38879
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2014-12-08
|
Emphasis |
N: ISOCYAN8
|
Case Closed |
2015-02-10
|
Related Activity
Type |
Inspection |
Activity Nr |
987010 |
Health |
Yes |
|
|
339870107
|
0419400
|
2014-07-24
|
154 LIPFORD RD, VERONA, MS, 38879
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2014-08-19
|
Emphasis |
N: LEAD, P: LEAD, N: ISOCYAN8
|
Case Closed |
2015-03-16
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100305 G01 IV A |
Issuance Date |
2014-10-07 |
Abatement Due Date |
2014-11-03 |
Current Penalty |
2025.0 |
Initial Penalty |
2025.0 |
Final Order |
2014-11-04 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: (a) Lab - On or about August 20, 2014 power taps were used as a substitute for fixed wiring. Plugged into the power tap were weight machine, fans and computers. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19101200 F06 II |
Issuance Date |
2014-10-07 |
Abatement Due Date |
2014-11-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-11-04 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical: (a) Work Area - On or about August 20, 2014 the employer did not label the container of silicon. |
|
|
339248296
|
0419400
|
2013-08-02
|
154 LIPFORD RD, VERONA, MS, 38879
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-08-02
|
Emphasis |
L: FALL
|
Case Closed |
2013-08-14
|
Related Activity
Type |
Referral |
Activity Nr |
836960 |
Safety |
Yes |
|
|
315307223
|
0419400
|
2012-02-08
|
154 LIPFORD RD, VERONA, MS, 38879
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-02-09
|
Emphasis |
S: FALL FROM HEIGHT, S: COMMERCIAL CONSTR, L: FALL, L: EISAOF
|
Case Closed |
2012-03-30
|
Related Activity
Type |
Complaint |
Activity Nr |
208572974 |
Safety |
Yes |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100179 B05 |
Issuance Date |
2012-03-06 |
Abatement Due Date |
2012-03-09 |
Current Penalty |
2167.0 |
Initial Penalty |
2167.0 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
01 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100179 I |
Issuance Date |
2012-03-06 |
Abatement Due Date |
2012-03-09 |
Current Penalty |
2167.0 |
Initial Penalty |
2167.0 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
01 |
|
|