Search icon

Seminole Furniture, LLC

Company Details

Name: Seminole Furniture, LLC
Jurisdiction: MISSISSIPPI
Business Type: Limited Liability Company
Status: Dissolved
Effective Date: 15 Jun 2011 (14 years ago)
Business ID: 984704
ZIP code: 38860
County: Chickasaw
State of Incorporation: MISSISSIPPI
Principal Office Address: 269 SOUTH CARTER ST.OKOLONA, MS 38860
Historical names: Madison Ridge, LLC

Member

Name Role Address
MICHAEL HYDE Member 155 BOYKIN CREEK RD, RICHTON, MS 39476
Mark Dauler Member 5131 Hwy 9 North, Pontotoc, MS 38863
Ricky Stroupe Member 214 County Road 1046, Tupelo, MS 38801

Filings

Type Status Filed Date Description
Admin Dissolution Filed 2020-11-27 Action of Seminole Furniture, LLC: AR/RA
Notice to Dissolve/Revoke Filed 2020-08-28 Notice to Dissolve/Revoke
Agent Resignation Filed 2019-11-18 Agent Resignation For RICKY STROUPE
Annual Report LLC Filed 2019-11-18 Annual Report For Seminole Furniture, LLC
Annual Report LLC Filed 2019-04-18 Annual Report For Seminole Furniture, LLC
Annual Report LLC Filed 2018-01-31 Annual Report For Seminole Furniture, LLC
Amendment Form Filed 2017-08-28 Amendment For Seminole Furniture, LLC
Annual Report LLC Filed 2017-02-23 Annual Report For Seminole Furniture, LLC
Annual Report LLC Filed 2016-03-25 Annual Report For Seminole Furniture, LLC
Registered Agent Change of Address Filed 2016-02-23 Agent Address Change For Deas, W Lawrence

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344055538 0419400 2019-05-31 270 S CARTER STREET, OKOLONA, MS, 38860
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2019-06-03
Emphasis P: AMPUTATE, N: AMPUTATE
Case Closed 2023-03-29

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100022 A01
Issuance Date 2019-07-18
Abatement Due Date 2019-08-09
Current Penalty 5626.0
Initial Penalty 5626.0
Final Order 2019-08-16
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms shall be kept clean and orderly and in a sanitary condition. (a) Pillow Blower- On or about May 31, 2019 the employer did not ensure that work floor was kept clean and clear of debris. Employees were exposed to trip hazards when working on a work floor covered with fiberfill.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100147 C04 I
Issuance Date 2019-07-18
Abatement Due Date 2019-08-16
Current Penalty 13127.0
Initial Penalty 13127.0
Final Order 2019-08-16
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section. (a) Facility - On or about May 31, 2019 the employer did not have procedures specific to each machine developed, documented and utilized for the control of energy sources of equipment, such as but not limited to, chop saws, rip saws, panels saw, and CNC router when employees performed servicing and maintenance exposing employees to amputation hazards.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100147 C06 I
Issuance Date 2019-07-18
Abatement Due Date 2019-08-16
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-08-16
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) Facility - On or about May 31, 2019 the employer had not performed the required periodic inspection of their energy control procedures for equipment such as but not limited to, CNC router, panel saw, chop saws, and rip saws prior to employees performing servicing and maintenance exposing employees to caught-in and struck-by hazards.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19100147 C07 I
Issuance Date 2019-07-18
Abatement Due Date 2019-08-16
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-08-16
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: (a) Facility - On or about May 31, 2019 the employer had not provided adequate training to the employees on energy control procedures for equipment such as but not limited to, chop saws, rip saws, CNC router and panel saw prior to employees performing servicing and maintenance exposing employees to caught-in and struck-by hazards.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100213 A09
Issuance Date 2019-07-18
Abatement Due Date 2019-08-09
Current Penalty 9377.0
Initial Penalty 9377.0
Final Order 2019-08-16
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.213(a)(9): All belts, pulleys, gears, shafts, and moving parts shall be guarded in accordance with the specific requirements of 1910.219. (a) Chop Saw 1 - On or about May 31, 2019 the employer did not ensure that the belts and pulley of the saw were guarded, exposing employees to a caught-in hazard. (b) Chop Saw 2 - On or about May 31, 2019 the employer did not ensure that the belts and pulley of the saw were guarded, exposing employees to a caught-in hazard. (c) Panel/Gang Rip Saw - On or about May 31, 2019 the employer did not ensure that the chain and sprocket of the saw were guarded, exposing employees to a caught-in hazard.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100213 B06
Issuance Date 2019-07-18
Current Penalty 13127.0
Initial Penalty 13127.0
Final Order 2019-08-16
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.213(b)(6): Operating treadle(s) on woodworking machine(s) were not protected against unexpected or accidental tripping. (a) Chop Saw 1 - On or about May 31, 2019 the employer did not provide adequate guarding for the foot pedal on the chop saw, exposing the operator to amputation hazards.
Citation ID 01005
Citaton Type Serious
Standard Cited 19100213 C02
Issuance Date 2019-07-18
Abatement Due Date 2019-08-09
Current Penalty 13127.0
Initial Penalty 13127.0
Final Order 2019-08-16
Nr Instances 2
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.213(c)(2): Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator. (a) Rip Saw 1 - On or about May 31, 2019 the employer did not ensure that the saw utilized a spreader, exposing employees to a struck-by and amputation hazard. (b) Rip Saw 2 - On or about May 31, 2019 the employer did not ensure that the saw utilized a spreader, exposing employees to a struck-by and amputation hazard. (c) Rip Saw 3 - On or about May 31, 2019 the employer did not ensure that the saw utilized a spreader, exposing employees to a struck-by and amputation hazard.
Citation ID 01006
Citaton Type Serious
Standard Cited 19100213 H01
Issuance Date 2019-07-18
Abatement Due Date 2019-08-09
Current Penalty 9377.0
Initial Penalty 9377.0
Final Order 2019-08-16
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.213(h)(1): The upper hood shall completely enclose the upper portion of the blade down to a point that will include the end of the saw arbor. The upper hood shall be constructed in such a manner and of such material that it will protect the operator from flying splinters, broken saw teeth, etc., and will deflect sawdust away from the operator. The sides of the lower exposed portion of the blade shall be guarded to the full diameter of the blade by a device that will automatically adjust itself to the thickness of the stock and remain in contact with stock being cut to give maximum protection possible for the operation being performed. (a) Delta Radial Arm Saw - On or about May 31, 2019 the employer did not ensure that the lower portion of the blade was guarded, exposing employees to an amputation hazard.
Citation ID 01007
Citaton Type Serious
Standard Cited 19100219 C04 I
Issuance Date 2019-07-18
Abatement Due Date 2019-08-09
Current Penalty 13127.0
Initial Penalty 13127.0
Final Order 2019-08-16
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft. (a) Picker - On or about May 31, 2019 the employer did not ensure that the rotating shaft on the side of the picker was guarded, exposing employees to a caught-in hazard.
340912658 0419400 2015-08-26 270 S CARTER STREET, OKOLONA, MS, 38860
Inspection Type FollowUp
Scope Partial
Safety/Health Health
Close Conference 2015-08-26
Case Closed 2015-09-17

Related Activity

Type Inspection
Activity Nr 1053283
Health Yes
340532837 0419400 2015-04-01 270 S CARTER STREET, OKOLONA, MS, 38860
Inspection Type Referral
Scope Partial
Safety/Health Health
Close Conference 2015-04-15
Emphasis L: FORKLIFT
Case Closed 2015-07-28

Related Activity

Type Referral
Activity Nr 969624
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100095 B01
Issuance Date 2015-06-05
Abatement Due Date 2015-06-22
Current Penalty 1822.8
Initial Penalty 3038.0
Final Order 2015-07-09
Nr Instances 1
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.95(b)(1): When employees are subjected to sound exceeding those listed in Table G-16, feasible administrative or engineering controls shall be utilized. If such controls fail to reduce sound levels within the levels of Table G-16, personal protective equipment shall be provided and used to reduce sound levels within the levels of the table: (a) Frame - On or about April 15, 2015 the framer was/were exposed to continuous noise at 150.4 % of the permissible daily noise (eight hour time weighted average sound level of 90 decibels) or an equivalent sound level of approximately 93.0 decibels during the 350 minutes sampling period on April 15, 2015. Exposure calculations included a zero increment for the time not sampled.
Citation ID 02001
Citaton Type Other
Standard Cited 19100095 C01
Issuance Date 2015-06-05
Abatement Due Date 2015-07-21
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-07-09
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: (a) Rip Saw - On or about April 15, 2015 the rip saw operator was/were exposed to continuous noise at 91.8 % of the permissible daily noise (eight hour time weighted average sound level of 90 decibels) or an equivalent sound level of approximately 89.2 decibels during the 350 minutes sampling period on April 15, 2015. Exposure calculations included a zero increment for the time not sampled. (a) Blower - On or about April 15, 2015 the blower operator was/were exposed to continuous noise at 66.5% of the permissible daily noise (eight hour time weighted average sound level of 90 decibels) or an equivalent sound level of approximately 87.0 decibels during the 350 minute sampling period on April 15, 2015. Exposure calculations included a zero increment for the time not sampled.
Citation ID 02002
Citaton Type Other
Standard Cited 19100132 D01
Issuance Date 2015-06-05
Abatement Due Date 2015-07-21
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-07-09
Nr Instances 1
Nr Exposed 25
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE): (a) Frame - On or about April 1, 2015 the employer had not developed a hazard assessment to determine where personal protective equipment would be required.
Citation ID 02003
Citaton Type Other
Standard Cited 19100141 D02 II
Issuance Date 2015-06-05
Abatement Due Date 2015-07-21
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-07-09
Nr Instances 1
Nr Exposed 25
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.141(d)(2)(ii): Lavatories were not provided with hot and cold, or tepid running water: (a) Blower - On or about April 15, 2015 the restrooms were not equipped with hot water.
340449008 0419400 2015-03-11 270 S CARTER STREET, OKOLONA, MS, 38860
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2015-03-11
Emphasis N: AMPUTATE
Case Closed 2015-05-05

Related Activity

Type Referral
Activity Nr 967543
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100147 C01
Issuance Date 2015-04-08
Abatement Due Date 2015-05-07
Current Penalty 3780.0
Initial Penalty 6300.0
Final Order 2015-05-04
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. (a) Picker - On or about March 11, 2015 the facility does not have a written energy control program that has equipment listed, specific lock out procedures to deenergize the equipment, person/s responsible for conducting periodic inspections and certification of training of affected and authorized employees that is related to their specific machinery.

Date of last update: 15 Feb 2025