Name: | Sonic Drive-In of Lucedale, LLC |
Jurisdiction: | MISSISSIPPI |
Business Type: | Limited Liability Company |
Status: | Dissolved |
Effective Date: | 12 Apr 2012 (13 years ago) |
Business ID: | 999851 |
ZIP code: | 39452 |
County: | George |
State of Incorporation: | MISSISSIPPI |
Principal Office Address: | 182 WINTER STREETLUCEDALE, MS 39452 |
Name | Role | Address |
---|---|---|
Harvey, Caleb M | Agent | 299 Stallings Bridge Road, Tylertown, MS 39667 |
Name | Role | Address |
---|---|---|
Cary L Harvey | Member | 299 STALLINGS BRIDGE RD, TYLERTOWN, MS 39667 |
Chat Inc. | Member | 221 Ball Ave, Tylertown, MS 39667 |
Robert T. Jackson, Jr. | Member | 309 South 40th AvenuePost Office Box 15517, Hattiesburg, MS 39404-5517 |
Type | Status | Filed Date | Description |
---|---|---|---|
Admin Dissolution | Filed | 2018-12-10 | Admin Dissolution: AR |
Notice to Dissolve/Revoke | Filed | 2018-09-07 | Notice to Dissolve/Revoke |
Annual Report LLC | Filed | 2017-03-21 | Annual Report For Sonic Drive-In of Lucedale, LLC |
Annual Report LLC | Filed | 2016-03-23 | Annual Report For Sonic Drive-In of Lucedale, LLC |
Annual Report LLC | Filed | 2015-01-12 | Annual Report For Sonic Drive-In of Lucedale, LLC |
Annual Report LLC | Filed | 2014-03-24 | Annual Report LLC |
Amendment Form | Filed | 2013-03-20 | Amendment |
Annual Report LLC | Filed | 2013-03-06 | Annual Report LLC |
Formation Form | Filed | 2012-04-12 | Formation |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
340164078 | 0419400 | 2015-01-05 | 182 WINTER STREET, LUCEDALE, MS, 39452 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 929429 |
Safety | Yes |
Health | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100022 A02 |
Issuance Date | 2015-04-06 |
Abatement Due Date | 2015-04-14 |
Current Penalty | 1230.0 |
Initial Penalty | 2800.0 |
Final Order | 2015-04-27 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.22(a)(2): Floors(s) of workroom(s) were not maintained, so far as possible, in a dry condition. (a) Freezer and Ice Machine - On or about January 5, 2015, the following slip hazards were noted: 1. Walk-In Freezer - Freezer floor was covered with ice. 2. Ice Machine - Crushed ice was removed from the ice machine and dumped on the floor in front of the machine. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19100037 A03 |
Issuance Date | 2015-04-06 |
Abatement Due Date | 2015-04-14 |
Current Penalty | 800.0 |
Initial Penalty | 1600.0 |
Final Order | 2015-04-27 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: (a) Rear Door - On or about January 5, 2015, the rear door was blocked by pallets of bread. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19100303 G02 I |
Issuance Date | 2015-04-06 |
Abatement Due Date | 2015-04-14 |
Current Penalty | 1000.0 |
Initial Penalty | 2000.0 |
Final Order | 2015-04-27 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or other forms of approved enclosures, or other means listed under this provision: (a) Walk-In Refrigerator - On or about January 5, 2015 the walk-in refrigerator light switch cover was missing. The light switch is located at the walk-in refrigerator entrance door. |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19100304 G05 |
Issuance Date | 2015-04-06 |
Abatement Due Date | 2015-04-14 |
Current Penalty | 1000.0 |
Initial Penalty | 2000.0 |
Final Order | 2015-04-27 |
Nr Instances | 2 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: (a) General Manager Desk and Grill - On or about January 5, 2015 the electrical receptacles located under the grill and next to the general manager desk were not grounded. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19100023 A08 |
Issuance Date | 2015-04-06 |
Current Penalty | 340.0 |
Initial Penalty | 340.0 |
Final Order | 2015-04-27 |
Nr Instances | 1 |
Nr Exposed | 3 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk were not guarded: (a) Speaker Station - On or about January 5, 2015 the floor drain located at a speaker station next the general manager desk had a broken cover. |
Citation ID | 02002 |
Citaton Type | Other |
Standard Cited | 19100303 B02 |
Issuance Date | 2015-04-06 |
Abatement Due Date | 2015-04-14 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2015-04-27 |
Nr Instances | 1 |
Nr Exposed | 3 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling. (a) Under Work Table - On or about January 5, 2015 energized electrical wires protruded from a conduit located under a work table at the front entrance of the restaurant. The end of the wires did have wire caps. The wires were next a floor drain. |
Citation ID | 02003 |
Citaton Type | Other |
Standard Cited | 19100305 G01 IV A |
Issuance Date | 2015-04-06 |
Abatement Due Date | 2015-04-14 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2015-04-27 |
Nr Instances | 3 |
Nr Exposed | 3 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables were used as a substitute for the fixed wiring of a structure. (a) Restaurant - On or about January 5, 2015 extension cords were used as permanent wiring in the main area of the restaurant. |
Citation ID | 02004 |
Citaton Type | Other |
Standard Cited | 19100305 G01 IV B |
Issuance Date | 2015-04-06 |
Abatement Due Date | 2015-04-14 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2015-04-27 |
Nr Instances | 3 |
Nr Exposed | 22 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and cables were run through holes in walls, ceilings, or floors. (a) Restaurant - On or about January 5, 2015 extension cords were routed through the ceiling in the main area of the restaurant. |