346822943
|
0419400
|
2023-07-11
|
3244 HWY 51 SOUTH, WINONA, MS, 38967
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-07-11
|
Emphasis |
N: AMPUTATE, P: AMPUTATE
|
Case Closed |
2023-12-20
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 C06 I |
Issuance Date |
2023-09-29 |
Abatement Due Date |
2023-10-24 |
Current Penalty |
5692.8 |
Initial Penalty |
9488.0 |
Final Order |
2023-10-19 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. (a) Facility - On or about July 11. 2023 the employer had not performed periodic inspections of their energy control procedures, exposing employees to caught-in and struck-by hazards. |
|
|
345483838
|
0419400
|
2021-08-18
|
3244 HWY 51 SOUTH, WINONA, MS, 38967
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2021-08-18
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2023-03-31
|
Related Activity
Type |
Referral |
Activity Nr |
1797665 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2021-09-29 |
Abatement Due Date |
2021-11-01 |
Current Penalty |
5908.8 |
Initial Penalty |
9848.0 |
Final Order |
2021-11-01 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1):Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc. (a) Stud Welder - On or about August 18, 2021 employer did not install guarding exposing operators to a pinch point. |
|
|
345070684
|
0419400
|
2020-12-17
|
3244 HWY 51 SOUTH, WINONA, MS, 38967
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2020-12-17
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2023-04-06
|
Related Activity
Type |
Referral |
Activity Nr |
1705597 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100147 C06 I |
Issuance Date |
2021-04-14 |
Abatement Due Date |
2021-05-06 |
Current Penalty |
0.0 |
Initial Penalty |
9753.0 |
Final Order |
2021-05-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. (a) Facility - On or about December 17, 2020 the employer had not performed periodic inspections of their energy control procedures, exposing employees to caught-in hazards. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100147 C07 I A |
Issuance Date |
2021-04-14 |
Abatement Due Date |
2021-05-06 |
Current Penalty |
5000.0 |
Initial Penalty |
0.0 |
Final Order |
2021-05-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control. (a) LVD Hydraulic Brake Press - On or about December 17, 2020 the employer did not train employees that perform set-up as authorized employees, exposing employees to a caught-in and struck-by hazards. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100147 D03 |
Issuance Date |
2021-04-14 |
Abatement Due Date |
2021-05-06 |
Current Penalty |
7000.0 |
Initial Penalty |
13653.0 |
Final Order |
2021-05-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(d)(3): Machine or equipment isolation. All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s). (a) LVD Hydraulic Brake Press - On or about December 17, 2020 employees did not isolate the electrical, hydraulic, and gravity energy sources prior to performing set-up exposing to the employees to struck-by and caught-in hazards. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100147 D04 I |
Issuance Date |
2021-04-14 |
Abatement Due Date |
2021-05-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2021-05-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees. (a) LVD Hydraulic Brake Press - On or about December 17, 2020 employees did not use a lockout device to isolate the electrical, hydraulic and gravity energy sources prior to performing set-up exposing the employees to struck-by and caught-in hazards. |
|
|
344221478
|
0419400
|
2019-08-08
|
3244 HWY 51 SOUTH, WINONA, MS, 38967
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2019-08-08
|
Case Closed |
2023-03-29
|
Related Activity
Type |
Complaint |
Activity Nr |
1483247 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100022 A01 |
Issuance Date |
2019-11-13 |
Abatement Due Date |
2019-12-06 |
Current Penalty |
3100.0 |
Initial Penalty |
5115.0 |
Final Order |
2019-12-13 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.22(a)(1): The employer failed to provide a clean and sanitary condition for all places of employment, passageways, storerooms, service rooms, and walking-working surfaces. (a) On or about August 8, 2019, the paint spray area was not kept in a clean and sanitary condition. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100107 E02 |
Issuance Date |
2019-11-13 |
Abatement Due Date |
2019-12-06 |
Current Penalty |
4100.0 |
Initial Penalty |
6819.0 |
Final Order |
2019-12-13 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.107(e)(2): The quantity of flammable or combustible liquids kept in the vicinity of spraying operation(s) exceeded the minimum required for operation: On or about, August 8, 2019, more than one days use of flammable liquids were kept in the vicinity of spraying operations. |
|
Citation ID |
01003 |
Citaton Type |
Other |
Standard Cited |
19100134 F05 |
Issuance Date |
2019-11-13 |
Abatement Due Date |
2019-12-06 |
Current Penalty |
3000.0 |
Initial Penalty |
6819.0 |
Final Order |
2019-12-13 |
Nr Instances |
2 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(f)(5): The fit test was not administered using an OSHA-accepted qualitative fit test or quantitative fit test protocol: (a) On or about August 8, 2019, employees were administered fit test with beards. |
|
Citation ID |
01004 |
Citaton Type |
Other |
Standard Cited |
19100134 G01 I A |
Issuance Date |
2019-11-13 |
Abatement Due Date |
2019-12-06 |
Current Penalty |
3000.0 |
Initial Penalty |
6819.0 |
Final Order |
2019-12-13 |
Nr Instances |
2 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: (a)) On or about August 8, 2019, employees donned respirators with facial hair that interfered with the seal of the tight fitting full face mask respirator. Employees were exposed to an inhalation hazard. (b) On or about August 8, 2019, employees were using tight-fitting facepieces with head socks that interfered with the face-to-facepiece seal of the respirator. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19101200 F06 II |
Issuance Date |
2019-11-13 |
Current Penalty |
4700.0 |
Initial Penalty |
6819.0 |
Final Order |
2019-12-13 |
Nr Instances |
2 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical On or about August 8, 2019; employer did not affix any labels to the two containers in the pre-wash area. |
|
|
342467560
|
0419400
|
2017-07-12
|
3244 HWY 51 SOUTH, WINONA, MS, 38967
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-07-12
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2018-08-24
|
Related Activity
Type |
Referral |
Activity Nr |
1239352 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100179 J03 |
Issuance Date |
2017-08-14 |
Abatement Due Date |
2017-09-06 |
Current Penalty |
5542.0 |
Initial Penalty |
5542.0 |
Final Order |
2017-09-07 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.179(j)(3): Periodic inspection. Complete inspections of the crane shall be performed at intervals as generally defined in paragraph (j)(1)(ii)(b) of this section, depending upon its activity, severity of service, and environment, or as specifically indicated below. These inspections shall include the requirements of paragraph (j)(2) of this section and in addition, the following items. Any deficiencies such as listed shall be carefully examined and determination made as to whether they constitute a safety hazard: (a) K22 Crane - On or about July 12, 2017 employer did not check locking connection pins where bridge is connected to the runway during the periodic crane inspection. |
|
|
342451838
|
0419400
|
2017-07-06
|
3244 HWY 51 SOUTH, WINONA, MS, 38967
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-07-06
|
Emphasis |
N: AMPUTATE, P: AMPUTATE
|
Case Closed |
2017-08-29
|
Related Activity
Type |
Referral |
Activity Nr |
1231595 |
Safety |
Yes |
|
|